PoE Power & Extender Calculator
Check whether your PoE run — including extenders — will deliver enough power.
Sufficient power
Margin: +10 W
Power required
12W
12 W × 1 device
Power delivered
22W
at the device end of the run
Segment-by-segment breakdown
| Segment | Length | Cable loss | After cable | After extender |
|---|---|---|---|---|
| Segment 1: Switch → Extender 1 | 100 m | −3 W | 27 W | 25 W−2 W overhead |
| Segment 2: Extender 1 → Device | 100 m | −3 W | 22 W | — |
| Power delivered at device | 22 W | |||
Segment 1: Switch → Extender 1
Length100 m
Cable loss−3 W
After cable27 W
After extender25 W−2 W
Segment 2: Extender 1 → Device
Length100 m
Cable loss−3 W
After cable22 W
After extender—
Power delivered at device22 W